Siemens SIDOOR AT40 System Manual page 65

Automatic door control
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
4.6 Technical specifications
Article number
Input voltage
per DC input, min.
per DC input, max.
Input current
per DC input, min.
per DC input, max.
Digital outputs
Relay outputs
Switching capacity of con-
tacts
at 30 V DC,
min.
at 30 V DC,
max.
at 50 V DC,
min.
at 50 V DC,
max.
at 230 V AC,
min.
at 230 V AC,
max.
Mechanical data
Opening width of door,
min.
Opening width of door,
max.
Weight of door, max.
Operating cycle fre-
quency of door, max.
Counterforce, max.
Kinetic energy, max.
Counterweight
with SIDOOR M2
geared motor, max.
with SIDOOR M3
geared motor, max.
with SIDOOR M4
geared motor, max.
with SIDOOR M5
geared motor, max.
64
6FB1111-
6FB1111-
0AT11-3AT0
1AT10-3AT3
10 V; Observe polarity !
28 V; Observe polarity !
9 mA
27 mA
0.01 A
0.5 A
0.3 m
5 m
600 kg
180 1/h
80 N
100 J
4 kg
6 kg
8 kg
8 kg
6FB1111-
6FB1111-
0AT10-3AT2
1AT10-3VE2
1 A
0.01 A; 50 V DC switching voltage
not released for NFPA-relevant
countries
1 A; 50 V DC switching voltage not
released for NFPA-relevant coun-
tries
0.01 A
1 A
Door control units SIDOOR AT40 and ATD400V for elevators
System Manual, 06/2018, A5E42192709-AC