306 Configuration

Configuring SMS

To configure the SMS, set the FSO parameters listed below to appropriate values
using the Drive composer pro PC tool. See parameter groups
Safety
on page 322.
There are two different versions of the SMS function. Select the required version with
parameter
200.71 SMS activity and
For more information on the SMS function, see page 142.

How to configure SMS, version 1

Example: The figure below shows an example of the SMS, version 1 set-up:
• SMS function version 1 activated
• positive limit 1800.0 rpm
• negative limit -1200.0 rpm
• SSE function configured as immediate STO
(SSE.13 SSE function
• See also section
Speed
version.
(200.71 SMS activity and version
(SMS.14 SMS trip limit positive e
(SMS.13 SMS trip limit negative
= Immediate STO).
Fine-tuning the configuration
200.71
= Version 1
SSE activated
SMS
on page
= 1800 rpm)
= -1200 rpm)
on page 314.
SMS.14
= 1800 rpm
Time
SMS.13
= -1200 rpm
348
and
= Version 1)