How to configure SSE with time monitoring

For more information on the SSE function with time monitoring, see page 103.
Example: The figure below shows an example of the SSE function with time
monitoring set-up:
• SAR0 emergency ramp (always with the SSE function)
• SSE with time monitored ramp
SSE.14 SSE monitoring method
• security delay for activating the drive STO: 2000 ms
(SSE.15 SSE delay for STO
• automatic acknowledgement
• redundant emergency stop button connected to input
(SSE.11 SSE input A
• single output connected
• zero speed limit for activating the drive STO: 90 rpm
(FSOGEN.51 Zero speed without encoder
(when an encoder is used:
• delay for activating the drive STO after the speed limit has been reached: 0 ms
(SSE.16 SSE ramp zero speed delay for STO
• speed limit activated brake not in use
(SBC.15 SSE/SS1 SBC speed
• See also section
Inputs
SSE.11
= DI X113:1 & X114:1
SSE.12
= None
FSOGEN.51
= 90 rpm
SBC.15
= 0 rpm
(SSE.13 SSE function
= Time)
= 2000 ms)
(STO.02 STO acknowledgement
= DI X113:1 & X114:1)
(SSE.21 SSE output
FSOGEN.52 Zero speed with encoder
= 0 rpm)
Fine-tuning the configuration
STO.02
SSE.13
SSE.14
Speed
SSE.15
SSE activated
= Emergency ramp,
= DO X113:9)
= 90 rpm)
= 0 ms)
on page 314.
= Automatic
= Emergency ramp
= Time
= 2000 ms
SSE.16
= 0 ms
STO activated
Configuration 287
= Automatic)
= 90 rpm)
Outputs
SSE.21
= DO X113:9
SSE.22
= None
Time