Maintenance; Contents Of This Chapter; Planning; Tools - ABB FSO-21 User Manual

Safety functions module
Hide thumbs Also See for FSO-21:
Table of Contents

Advertisement

Maintenance

Contents of this chapter

This chapter explains replacement of the FSO and FSE modules in case of a module
failure, reinstalling the FSO module to another drive, updating the firmware of the
drive where the FSO is installed, factory reset, FSO update and decommissioning as
well as proof tests.
WARNING! Read and obey the instructions in chapter
Safety instructions in the drive hardware manual. If you ignore them, injury or
death, or damage to the equipment can occur.

Planning

All maintenance and the repair actions on a safety critical system are safety critical.
You must plan and perform them accordingly.

Tools

You need the Drive composer pro PC tool to perform the maintenance procedures.

FSO module replacement

If the FSO module fails to operate, you have to replace it with a new one; the module
is not repairable.
Note: When the FSO module is in the Fail-safe mode, it can be recovered by
switching the power off and on, by rebooting the FSO with drive parameter 96.09
FSO reboot (see the drive firmware manual) or by pressing the Boot FSO button in
Drive composer pro.
Maintenance 417
15
Safety
and chapter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents