How to configure SLSn with ramp monitoring

Example: The figure below shows an example of the SLS2 function with ramp
monitoring set-up:
• SLS2 function activated
• monitored deceleration ramp
(SLSx.03 SLS activation monitoring method
• deceleration ramp and monitoring limits according SAR1 parameters (see section
Configuring SAR
• automatic acknowledgement
• redundant SLS activation button connected to input
(SLSx.21 SLS2 input
• single output connected
• positive limits: SLS 1200.0 rpm, trip limit 1320.0 rpm
(200.33 SLS2 limit positive
SLSx.23 SLS2 trip limit positive
• negative limits: SLS -900.0 rpm, trip limit -1020.0 rpm
(200.32 SLS2 limit negative
SLSx.22 SLS2 trip limit negative
• See also section
Note: The difference between the SLS limit and the corresponding SLS trip limit must
be at least 0.1 rpm.
Note: If you also use the SMS function, the SLS trip limits positive and negative must
be below the speed defined by parameter
defined by parameter
(200.31 SLS2 activity and version
on page 294)
(SLSx.02 SLS acknowledgement
= DI X113:2 & X114:2)
(SLSx.24 SLS2 output
= 1200 rpm,
= 1320 rpm).
= -900 rpm,
= -1020 rpm).
Fine-tuning the configuration
SMS trip limit
negative, respectively.
= Ramp)
= DO X114:7)
on page 314.
SMS trip limit positive
Configuration 297
= Version 1)
= Automatic)
and above the speed