Load Current Settings from Configuration Database

Load Current Settings from Configuration Database

Definition:
Allows the configuration settings contained in a selected database index to
be loaded to current, active configuration settings.
Serial Cmd:
<K255-,index>
Example:
<K255-,5>
This command phrase loads the configuration settings contained in database index 5 to
current, active configuration settings.
Load Current Settings from Configuration Database by ESP
Notes on Symbol Type
• The current DataBar Expanded status does not change if it is configured as Enabled
(Stacked) and the database DataBar Expanded status is Enabled.
• The current DataBar-14 status does not change if it is configured as Enabled (Stacked)
and the database DataBar Expanded status is Enabled.
• Data Matrix ECC level is determined by the current settings and not by database settings.
Therefore, the database does not know which ECC level to enable, and has no effect on
current Data Matrix ECC settings.
12-16
Click the Load Index to Current
button to load configuration settings
from the selected index to current,
active settings.