Setup Button - Omron MicroHAWK Integration Manual

Table of Contents

Advertisement

Setup Button

Setup Button

The Setup button has four positions, selectable by the length of time the button is held
down. Each position can be programmed for any of eight options.
Definition:
Serves as a master switch to enable/disable the Setup button status.
Serial Cmd:
<K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
2 = Trigger
3 = Unlatch Outputs
4 = Parameter Switch
Global Status
Disabled
When set to Disabled, the Setup button does not function.
Enabled
When selected, the Setup button is enabled and the function of each button position is
selected by the Setup Button Mode command.
Trigger
When selected, the Setup button acts as a trigger for the imager to start and end read
cycles. All other button operations are inactive.
In External
The read cycle endures for as long as the Setup button is pressed, unless
Level:
a timeout occurs and Timeout is enabled for End of Read Cycle.
In External
As with Level, Edge allows a read cycle to be initiated by pressing the
Setup button, but unlike Level, the read cycle ends with a good read output,
Edge:
a timeout, or a new trigger.
Unlatch Outputs
In this configuration, the Setup button will unlatch any logic outputs that have been
latched.
Parameter Switch
The parameter switch toggles between custom defaults and power-on settings. The condition
is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.