Power On/Reset Counts
Power On/Reset Counts
Note: Power On/Reset Counts is a read-only command.
Power-On
Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Power-On uses a 16-bit counter that increments each time the reader is powered-on.
Resets
Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Resets uses a 16-bit counter that increments each time the reader is reset. This value is
reset at power-on.
Power-On Saves
Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Power-On Saves uses a 16-bit counter that increments each time an reader setting is
saved for power-on with a <Z> command.
Power-On Flash Saves
Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Power-On Flash Saves uses a 16-bit counter that increments each time an reader setting is
saved to the customer parameter section of flash memory with a <Zc> command.