Omron MicroHAWK Integration Manual page 114

Table of Contents

Advertisement

Calibration Options
Disabled
When this feature is disabled, the Window of Interest is not modified after the calibration
process is complete.
Row and Column
If the calibration process is successful, the Window of Interest will be modified to frame the
symbol as well as an additional margin area around the symbol, determined by the WOI
Margin parameter.
Row
If the calibration process is successful, the Window of Interest rows will be modified to
horizontally frame the symbol, plus an additional margin area around the symbol, determined
by the WOI Margin parameter.
Column
If the calibration process is successful, the Window of Interest columns will be modified to
vertically frame the symbol, plus an additional margin area around the symbol, determined
by the WOI Margin parameter.
Straight Line
This feature is intended for use with linear symbologies. If the calibration process is successful,
the orientation of the symbol is determined and the Window of Interest is modified according
to the symbol orientation. The scan line orientation is determined to be vertical if the
symbol tilt is between 225° and 315°, or between 45° and 135°. Otherwise, the scan line
will be horizontal.
If the symbol is vertical, the image column size will be set by the scan height parameter,
and will be configured for full row resolution. If the symbol is horizontal, the image row size
will be set by the scan height parameter, and will be configured for full column resolution.
The scan line will be centered in the middle of the symbol. If the symbol is tilted such that
the scan line will not pass completely through the symbol, the scan width will be adjusted
to include the entire symbol. Refer to the diagram below:
Straight Line Framed
This parameter is the same as "Straight Line", except that the Window of Interest will also
frame the scan line on the symbol length as well. The scan line includes the symbol plus
an additional margin area determined by the WOI Margin parameter.
5-6
MicroHAWK Engine Integration Guide

Hide quick links:

Advertisement

Table of Contents
loading