Configurable Output 1 - Omron MicroHAWK Integration Manual

Table of Contents

Advertisement

Configurable Output 1

Configurable Output 1

Usage:
This option provides discrete signalling to host software to control external
devices such as PLCs and relays. It is useful for routing, sorting, and to
prevent mis-packaging and mis-routing.
Definition:
Sets the discrete output functions for specific user-selected conditions.
Allows the user to set the conditions under which an output (or outputs) will
be activated.
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
Mismatch or No-Read
Options:
0 = Mismatch or No-Read
1 = Match (or Good Read)
2 = Mismatch
3 = No-Read
4 = Trend Analysis
5 = Symbol Quality
6 = Diagnostic Warning
7 = In Read Cycle
Note: If Output On is set to any mode containing Match or Mismatch, the transition
(switching) will only occur if Matchcode Type is enabled and Master Symbol(s) are
loaded into memory.
Mismatch or No-Read
Activates discrete output when the data does not match that of the master symbol or the
symbol has not been decoded before the end of the read cycle.
Match (or Good Read)
Activates a discrete output when the symbol data matches the master symbol.
Mismatch
Activates a discrete output whenever the symbol data does not match that of the master
symbol.
No-Read
Activates a discrete output whenever the symbol data is not decoded before the end of the
read cycle.
8-20
MicroHAWK Engine Integration Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents