ISO/IEC 16022 Symbol Quality Output 1

ISO/IEC 16022 Symbol Quality Output 1

Note: Output On under Output 1 Parameters must be set to Symbol Quality for this
output to function.
Under Output 1 Parameters, expand the Symbol Quality (ISO/IEC 16022) tree.
Output on Symbol Contrast
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 to an active state when Symbol Contrast
Threshold is met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default:
Disabled
Options:
0 = Disabled
Output on Print Growth
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 to an active state when Print Growth Threshold
is met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default:
Disabled
Options:
0 = Disabled
8-26
1 = Enabled
1 = Enabled