New Master Pin - Omron MicroHAWK Integration Manual

Table of Contents

Advertisement

New Master Pin

Definition:
If Matchcode and New Master Pin are enabled and the new master pin
is momentarily activated (must be active for a minimum of 10 ms) master
symbol information will be loaded into the database based on the next
read cycle that achieves a Good Read, starting with Index 1.
Serial Cmd:
<K225,status>
Default:
Disabled
Options:
0 = Disabled
New Master Load Status
Definition:
The new master status responds with the number of the next master
position to be loaded, where 0 represents "idle" or "no master to be
loaded."
Example: If the user has the Number of Master Symbols set to 1, and
then either sends a <G> or toggles an active New Master Pin, the state
will be 1, and prior to reading and effectively loading position 1, the
response to <NEWM> would be <NEWM/1>. Once a symbol has been
read and loaded, the status will be cleared: <NEWM/0>.
Serial Cmd:
<NEWM>
MicroHAWK Engine Integration Guide
1 = Enabled
Matchcode
10-13