Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU1 with CPU heat sink
1 memory modules
1 PSUs
Table 8: Minimum startup configuration - components
Cable
2 SATA cables
Table 9: Minimum startup configuration - cables
Ê Shut down the server, see section
page
50.
Ê Take the system down to its minimum startup configuration.
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server, see section
node" on page
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).