Appendix
13.3
Minimum startup configuration
Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU1 with CPU heat sink
1 memory modules
1 PSUs
Table 8: Minimum startup configuration - components
Cable
2 SATA cables
Table 9: Minimum startup configuration - cables
Ê Shut down the server, see section
page
50.
Ê Take the system down to its minimum startup configuration.
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server, see section
node" on page
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
452
Notes and reference
no TPM or expansion cards installed
installed in slot 1A, see section
sequence" on page 185
Notes and reference
448.
Upgrade and Maintenance Manual
"Shutting down the server node" on
"Controls and indicators on the server
"Memory
CX2550/60/70 M4