SXM2 extension tray
11.7
Replacing the SMX2 base board
Field Replaceable Unit
(FRU)
Tools:
Preliminary and main steps: PH2 / (+) No. 2 screw
11.7.1 Preliminary steps
Perform the following procedures:
"Disabling the boot watchdog functionality of ServerView Operations
Ê
Manager" on page 73
Ê Locate the desired server node with the ID button.
"Shutting down the server node" on page 50
Ê
Ê If applicable, remove all external cables from the server node.
"Removing the server node from the server enclosure" on page 51
Ê
Ê Remove all SXM2 heat sinks, see section
page
361.
Ê Remove all SXM2 extensions, see section
page
377.
"Removing the GPGPU / SXM2 extension tray" on page 53
Ê
Ê Remove the SXM2 riser cards, see section
on page 407
and
414
"Removing the SXM2 base board" on page
Upgrade and Maintenance Manual
Hardware: 45 minutes
"Removing liquid cooling (LC)" on
"Removing the SXM2 module" on
"Removing the SXM2 riser (R)"
415.
CX2550/60/70 M4