Configure Volume Flow Measurement For Liquid Applications; Configure Volume Flow Type For Liquid Applications - Emerson Micro Motion 1700 Configuration And Use Manual

Transmitters with analog outputs
Hide thumbs Also See for Micro Motion 1700:
Table of Contents

Advertisement

4.2
Configure volume flow measurement for liquid
applications
The volume flow measurement parameters control how liquid volume flow is measured
and reported.
The volume flow measurement parameters include:
Restriction
You cannot implement both liquid volume flow and gas standard volume flow at the same time. You
must choose one or the other.
4.2.1

Configure Volume Flow Type for liquid applications

Display
ProLink II
ProLink III
Field Communicator Configure > Manual Setup > Measurements > GSV > Volume Flow Type > Liquid
Overview
Volume Flow Type controls whether liquid or gas standard volume flow measurement will be
used.
Procedure
Set Volume Flow Type to Liquid.
Configuration and Use Manual
-
The frequency output will report the actual flow rate, and the actual flow rate will
be used in all internal processing.
If the mass flow rate drops below 10 g/sec, both outputs will report zero flow, and 0
will be used in all internal processing.
Volume Flow Type
Volume Flow Measurement Unit
Volume Flow Cutoff
Not available
ProLink > Configuration > Flow > Vol Flow Type > Liquid Volume
Device Tools > Configuration > Process Measurement > Flow
Configure process measurement
29