Emerson Micro Motion 1700 Configuration And Use Manual page 83

Transmitters with analog outputs
Hide thumbs Also See for Micro Motion 1700:
Table of Contents

Advertisement

Table 5-2:
Status alarms and Status Alarm Severity
Alarm code
Status message
Meter Verification Aborted Informational
A035
A100
mA Output 1 Saturated
A101
mA Output 1 Fixed
A102
Drive Overrange
A103
Data Loss Possible (Totals
and Inventories)
A104
Calibration in Progress
A105
Slug Flow
A106
Burst Mode Enabled
A107
Power Reset Occurred
A108
Basic Event 1 On
A109
Basic Event 2 On
A110
Frequency Output Satura-
ted
A111
Frequency Output Fixed
A112
Upgrade Transmitter Soft-
ware
A113
mA Output 2 Saturated
A114
mA Output 2 Fixed
A115
No External Input or Polled
Data
A118
Discrete Output 1 Fixed
A119
Discrete Output 2 Fixed
A131
Meter Verification in Pro-
gress: Outputs to Last
Measured Value
Configuration and Use Manual
(continued)
Default severity Notes
Applies only to transmitters with
Smart Meter Verification.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Informational
Applies only to flowmeters with the
standard core processor.
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Normal transmitter behavior; oc-
curs after every power cycle.
Informational
Applies only to basic events.
Informational
Applies only to basic events.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Applies only to systems with trans-
mitter software earlier than v5.0.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Can be set to either Informational or
Ignore, but cannot be set to Fault.
Informational
Applies only to transmitters with
Smart Meter Verification.
Configure device options and preferences
Configurable?
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
75