Emerson Micro Motion 1700 Configuration And Use Manual page 217

Transmitters with analog outputs
Hide thumbs Also See for Micro Motion 1700:
Table of Contents

Advertisement

Important
When reassembling the meter components, be sure to grease all O-rings.
Configuration and Use Manual
1. Reconnect the 4-wire cable between the core processor and the transmitter.
2. Replace the core processor lid.
3. Restore power to the transmitter.
For an integral installation:
1. Reconnect the 4-wire cable between the core processor and the transmitter.
2. Without pinching or stretching the wires, lower the transmitter onto the base,
inserting the cap screws into the slots.
3. Rotate the transmitter clockwise so that the cap screws are in the locked
position.
4. Tighten the cap screws, torquing to 20 to 30 in-lbs (2.3 to 3.4 N-m).
5. Restore power to the transmitter.
For a 9-wire remote installation:
1. Reconnect the 4-wire cable between the core processor and the transmitter.
2. Without pinching or stressing the wires, slide the mounting plate into place.
3. Rotate the mounting plate so that the screws are in the locked position.
4. Tighten the screws, torquing to 6 to 8 in-lbs (0.7 to 0.9 N-m).
5. Replace the end-cap.
6. Restore power to the transmitter.
Troubleshooting