12.13 Engineer Reset Mode

[TM4] By Engineer PIN
When this parameter is selected, the customer has the engineer PIN to reset one of those 3 alarms (Tamper,
Local only
burglar and panic).
When this parameter is selected, the customer doesn't have the engineer PIN.
Local / Remote
In this case the customer has to call up the installer to tell them the three-digit number on the keypad. The
installer will be able to generate a six-digit code (external code generator) to reset the alarm.
When this parameter is selected, the customer can arm the system without resetting the alarm by engineer
Local User can set
PIN.
(never used, because of
insurance guidelines)
Notice, the alarm info will stay at the panel, until somebody is resetting the panel with engineer access. This
parameter will disable the settings "Engineer Reset on"

12.14 ISDN Access type

12.15 IP Settings (using Sylcom)

12.15.1 IP Address

]
Enter the Sintony IP address, e.g. 143.99.16.120 and use IP Port 1 (08500)

12.15.2 IP Router

Enter the Sintony IP address router: used in special case with DSL lines and Network Address Translation
(NAT) function.
Siemens Building Technologies
Fire Safety & Security Products
NOTE
This menu is only active, if at least one parameter in the beforehand menu "Engineer reset on"
is set!
Choose the right protocol:
Point to Point (directly ISDN from a provider)
Point to Multipoint (behind a TVA )
NOTE
Those settings are only used when the TCP/IP functions of SMN42/43 (IP/GSM Module for Sintony)
are used.
IP parameters are stored only in the PR0 file, they are not downloaded into the control panel.
NOTE
Other settings have to be done, to establish a working IP connection;
Set "Up/Download Mode" to Level 1 in the menu System
Set the protocol to one of TCP/IP-Protocols in the menu ARC