9.12

Forced Set

Forced Set
This parameter defines whether or not the partition permits forced setting. Forced setting means that trig-
gered input lines are automatically bypassed when assigned partition is set.
However, all of the following conditions must be fulfilled:
bypassed.
forced setting)
The following four options are available for this parameter.
0 = No Authority
1 = Until Unset
2 = Until Input quiescent state
3 = Forced Set
9.13

Transmission

9.13.1 Burglar Alarm/P. Set
Part Set Transmission of
This parameter defines whether or not transmission is enabled on part set or unset in the event of a burglar

Burglar Alarm

alarm.
B = Enabled
-
9.13.2 Tamper Alarm/P. Set
Part Set Transmission of
This parameter defines whether or not transmission is enabled on part set or unset in the event of a tamper

Tamper Alarm

alarm.
T = Enabled
-
Siemens Building Technologies
Fire Safety & Security Products
Triggered input lines must be defined as capable of being bypassed.
Not more than the defined number of inputs (50% or ONE defined by parameter "bypass mode") may be
When setting with a PIN the user must have forced setting authority (setting via an input is equivalent to
Forced setting is not possible.
Forced setting is possible whereby the bypassed lines remain bypassed until assigned partition is
unset.
Forced setting is possible whereby the bypassed lines remain bypassed until assigned partition is
unset or the bypassed line is in quiescent state.
Forced setting possible whereby the bypassed lines immediately trigger an alarm when forced setting
takes place.
= Disabled
= Disabled
Partitions
57
07.2009