Outputs

8.2.34 Emergency 1-5 (1-2 for SI120)

Emergency Exit 1
This output is activated by the input "Emergency Exit 1". The activation duration is set in the partition pa-
rameters "Emergency Exit".
Emergency Exit 2
Same function as emergency output 1, but activated by "Emergency Exit 2" input.
Emergency Exit 3
Same function as emergency output 1, but activated by "Emergency Exit 3" input.
Emergency Exit 4
Same function as emergency output 1, but activated by "Emergency Exit 4" input.
Emergency Exit 5
Same function as emergency output 1, but activated by "Emergency Exit 5" input.

8.2.35 Universal 1 / Universal 2

Universal 1
This output is activated for corresponding activation time (127 seconds/minutes). If the activation time is 000,
the output remains active until a valid PIN is entered at the keypad, then the input will change to normal
state. The output is activated regardless of the state of the assigned partition (full set / part set / unset).
Precondition: Input Universal Input 1 has been triggered and the delay time is lapsed.
Universal 2
Acts on "Universal Inputs 2". Function is identical to "Universal 1".
8.2.36 Calendar output 1 – 2 (SI220 only)
Calendar Output 1 - 2
These outputs can be triggered via Calendar.
8.2.37 Remote Control 1 – 2
Remote Control 1
This output can be triggered via a telephone line with DTMF commands. It is activated for 2 seconds.
Remote Control 2
This output can be triggered via a telephone line with DTMF commands. It is activated for 2 seconds.

8.2.38 Video Recorder

Video Recorder
This output is activated for the programmed activation time (127 minutes) on a video alarm.
Alarm For Recorder
This output is activated if a burglar alarm is triggered in the assigned partition. It is reset when the partition is
France
switched to unset or if a valid PIN for this partition has been entered on an authorized remote keypad.

8.2.39 Burglar for Transmission

Burglar for transmission
This output is activated if a Burglar has to be transmitted.

8.2.40 Seismic Activation

Vibration
This output is used to test periodically seismic detector.
(Vault Sensor Test)
If a "Vault Sensor" input is programmed, this output is set for 5 seconds in a random time of between 30 and
90 minutes. With this output, the test generator for structure-borne sound can now be triggered in order to
test the vault sensor alarm inputs.
50
Siemens Building Technologies
Fire Safety & Security Products
NOTE
The emergency output function is, not active in the unset state.
NOTE
This output will not create an event log.
This means that this output type operates only in conjunction with a "Vault Sensor" input.