074: Technic alarm
075: Burglar alarm
076: unused
077: Tamper alarm
078: Fire alarm
079: Duress PIN
080: PIN Tamper
081: Line Fault
082: Remote Assistance
083: Call detection
084: Buying Time
085 – 144: Partition 1-6->
(X)
Part set P(X)
Full set P(X)
Restr. Full Set P(X)
Complete full set P(X)
Abort / confirm P(X)
Technic alarm P(X)
Burglar alarm P(X)
Panic alarm P(X) (D, CH,
F, ES)
Panic alarm P(X) (UK)
Tamper alarm P(X)
Fire P(X)
Siemens Building Technologies
Fire Safety & Security Products
Is transmitted if a technical alarm has been triggered in the system. Clear message after the end of the
technical alarm.
Is transmitted if a burglar alarm has been triggered in the system (in one of the partitions). Clear message
in accordance with the programming of the "Partitions system options" (TM53) and "Clear message" pa-
rameters in the engineer menu.
System input 076 has no function.
Is transmitted if a tamper alarm has been triggered in the system (in one of the partitions). In contrast to
the system tamper transmission; this line is also transmitted if one of the inputs with the tamper line type is
transmitted. This means that a transmission takes place under the following conditions.
Open central control unit or open E-bus components
Loss of E-bus components
Tamper of inputs with two terminating resistors
Tamper with programmed inputs.
Clear message for system tamper on alarm reset, for alarm inputs in accordance with the "Partitions Sys-
tem Options" TM53) and "Clear message" parameters in the engineer menu.
Is transmitted if a fire alarm has been triggered in the system (one of the partitions). Clear message on
alarm rest.
Is transmitted if a duress PIN has been entered (code PIN +2).
Is transmitted after 3 consecutive wrong code entries on the keypad.
Is transmitted if the telephone line is interrupted or the voltage drops below 20V.
Clear message when the line is again restored.
Transmitted if an input programmed to remote assistance is triggered or if a remote assistance is triggered
via and SAK (press key ? three times). Clear message directly after remote assistance transmission.
Is transmitted if the control panel has detected an incoming call.
Is transmitted if "Buy Time" action has been performed in the system.
Is transmitted if partition 1 is set to part set. Clear message when partition 1 unset.
Is transmitted if partition 1 is set to full set. Clear message when partition 1 unset.
Is transmitted if partition 1 is set to full set, but at least one input (line) is bypassed. Clear message when
the line is again restored (see "Partitions system options" (TM53), "Forced set options" parameters in the
engineer menu) or when partition 1 unset.
Is transmitted if the complete partition 1 (no input bypassed) is full set. Clear message when partition 1
unset.
Is transmitted if an alarm has been cancelled in partition 1 (see transmission verification method).
Is transmitted if a technical alarm was triggered in partition 1. Clear message after end of technic alarm.
Is transmitted if a burglar alarm has been triggered in partition 1. Clear message in accordance with "Parti-
tions system options" (TM53) and "Clear message" parameters in engineer menu.
Is transmitted if a panic alarm or a silent panic alarm was triggered in partition 1. Clear message after 10
seconds.
Is transmitted if a panic alarm or a silent panic alarm was triggered in partition 1. Clear message on alarm
reset.
Is transmitted if a tamper alarm has been triggered in the partition 1 (in one of the partitions). In contrast to
the partition 1 tamper transmission, this line is also transmitted if one of the inputs with the tamper line type
is transmitted. This means that a transmission takes place under the following conditions.
Open central control unit or open E-bus components
Loss of E-bus components
Tamper of inputs with two terminating resistors
Tamper with programmed inputs.
Clear message for partition 1 tamper on alarm reset, for alarm inputs in accordance with the "Partitions
System Options" TM53) and "Clear message" parameters in the engineer menu.
Is transmitted if a fire alarm has been triggered in the partition 1 (one of the partitions). Clear message on
alarm rest.
System Input Transmission
07.2009
83