6.3.2

Keyswitch Zone latching Full Set

Keyswitch Full Set
Brief description: external arming; blockschloss
Only one switch should be used per partition because otherwise the positions of the switches do not agree
clearly with the system state.
The assigned partition is switched from unset to full set or vice versa (two fixed states). If the partition is
already part set, this is unset and immediately afterpartitions set to full set. The switch affects an automatic
forced set, i.e. the triggered inputs and inputs which can be bypassed are automatically bypassed. The
partition is, however, not set to full set if the partition is in the "cannot full set" state (e.g. tamper is triggered
etc.)
Trigger input
Set input to normal state
6.3.3

Keysw. Full set blockschloss

Late Homecoming
Brief description: Late Homecoming; blockschloss
Only one switch should be used per partition because otherwise the position of the switches does not coin-
cide clearly with the system state.
The assigned partition is switched from full set to unset or vice versa (two fixed states). If, however, the
partition is part set, it is not set to full set but instead it can be set only to unset (late home coming circuit).
The switch causes an automatic forced set, i.e. the triggered inputs and inputs which can be bypassed are
automatically bypassed. The partition is, however, not set to full set if the partition is in the Cannot Full Set"
state (e.g. tamper protection triggered etc.).
From the "Unset" state:
From the "Part Set" state:
20
Siemens Building Technologies
Fire Safety & Security Products
Room
Bypass-
able
N
N
N
N
N
N
N
N
N
N
Synthetic Inputs are input types (internally created by the system) and not triggered
by a physical input.
full set.
unset.
Trigger input
full set.
Switch input to normal state
Trigger input
remains part set.
Switch input to normal state
NOTE
This function is specifically required for German VdS approval.
Delay
Chime
Seconds
Minutes
N
N
N
N
N
N
0 ... 127
0 ... 127
N
0 ... 127
0 ... 127
N
N
N
N
unset.
unset
07.2009