Detailed Description
2.9 Mode group, channel, program operation, reset response (K1)
2.9
Mode group, channel, program operation, reset response (K1)
2.9
2.9.1
Signals to mode group (DB11)
DB11, ...
DBX0.0
AUTOMATIC mode
Edge evaluation: no
Signal state 1 or
AUTOMATIC mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
AUTOMATIC mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant
DB11, ... DBX0.4 (operating mode, changeover inhibit) = 1
for ...
Corresponding to ....
DB11, ... DBX6.0 (active AUTOMATIC mode)
DB11, ...
DBX0.1
MDA mode
Edge evaluation: no
Signal state 1 or
MDA mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
MDA mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant
DB11, ... D0.4 (operating mode, changeover inhibit) = 1
for ...
Corresponding to ....
DB11, ... DBX6.1 (active MDA mode)
2-80
Signal(s) updated: cyclic
Signal(s) updated: cyclic
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0