6.3.30 BA Access Zone

Only part set delayed
Brief description: BA external; Internal delay (Reverse function to Input 25)
(Burglar Alarm Entry
On part set: Delayed entry and exit triggering in the assigned partition.
Route)
On full set: Direct triggering in the assigned partition.
DE, UK
If the input remains triggered to the end of the delay time on setting to part set, the partition is again unset.
All other country ver-
If the input remains triggered to the end of the delay time on setting to part set, the partition remains full set
sions
and an alarm is triggered.
Partition mode:
Unset
X
X
Partition parameters:
X =
1 =
2 =
3 =
5 =
7 =

6.3.31 BA Entry Route

Burglar Alarm Entry Route
(Special Delayed)
DE, UK
All other country versions
32
Siemens Building Technologies
Fire Safety & Security Products
Triggering only if "Buzzer On" in the keypad parameter is chosen.
Triggering only after delay.
Part set
Full set
Effects on the following outputs when the below partition parameters are preset:
X
External bell
1/7
7
2
Internal bell
X
Strobe light
1/7
X
Cannot full set
7
X
Alarm in memory
X
Block lock not released
5
5
Buzzer
X
Burglar alarm system transmission line
3/7
X
Burglar alarm partition transmission line
3/7
X
Transmission line input
3/7
Triggering regardless of the partition mode.
Triggering only if the external bell "When Part Set" in the partition parameter is chosen.
Triggering only if the internal bell "When Full Set" in the partition parameter is chosen.
Triggering only if "transmission" parameter is chosen.
Triggering only if "Buzzer On" in the keypad parameter is chosen.
Triggering only after delay.
Brief description: BA external delay; Internal delay
Delayed entry and exit triggering on Part and Full set in the assigned partition.
If the input remains triggered to the end of the delay time when setting to part set or full set, the partition is
again unset.
If the input remains triggered to the end of the delay time when setting to part set or full set, the partition
remains full set and an alarm is triggered.
Partition mode:
Unset
Part set
Full set
Effects on the following outputs when the below partition parameters are preset:
7
External bell
7
Strobe light
7
Alarm in memory
X
X
Block lock not released
5
Buzzer
X
Burglar alarm system transmission line
X
Burglar alarm partition transmission line..
X
Transmission line input
Partition parameters:
X =
Triggering regardless of the partition mode.
5 =
Triggering only if "Buzzer On" in the keypad parameter is chosen.
7 =
Triggering only after delay.
07.2009