Inputs
6.7

Delay

[TM51]. Delay of Inputs
Only those types of input which due to their function enable a delay can be delayed. The input types are
shown in the overview table Delayed inputs are normally used for the sensors in the exit and entry area.
There is only one delay time which applies to the entry and exit.
Description of "Technical Input" and "Universal Input" see in the particular function description.
Delayed Inputs
A delayed input does not trigger until after the delay time. For the delayed burglar alarm inputs this means
that the inputs are not set during setting until after the delay time. Triggered delay inputs enable the setting of
DE, UK
a partition, but lead to an automatic unset if they are still triggered after the delay time has expired. An alarm
during the delay time is prevented when setting to unset.
Delayed Inputs
A delayed input does not trigger until after the delay time. For the delayed burglar alarm inputs this means
that the inputs are not set during setting until after the delay time. Triggered delay inputs enable the setting of
All other
a partition, but lead to an alarm if still triggered after the delay time has expired. An alarm during the delay
country versions
time is prevented when setting to unset.
Input Follows Delay
These are inputs which themselves have no entry delay time but when set trigger an alarm, also delayed, if
an entry delay time is already running. The inputs follow the longest programmed entry delay time for this
partition. If this entry is triggered as the first, a burglar alarm is immediately triggered. The inputs follow only
one delayed input which is assigned to the same partition. If one delay time is assigned to these inputs, this
applies only as an exit delay.
Delay Time
Each input which can be delayed can have its own delay time. This makes it possible to program several
delayed inputs with different delay times in one partition.
Final Setting /
If an input type with the "exit delay terminator" function is programmed to one of these two types, all delay
Final Door Set
times run unlimited for the corresponding partition. All delay times are then ended by triggering the "Final
Set" input or by triggering the " Final Door Set " input.
Delays
The burglar alarm inputs are limited to a maximum delay time of 127 seconds. For these inputs, the delay is
(Seconds / Minutes)
always applied in seconds. In contrast to this, the delay time of "Technical" or "Universal" inputs can be much
longer. For these inputs, the input time can be defined as seconds or minutes.
Delay Time for Virtual
The delay time during setting is started after the main partition through which the virtual partition is set is in
Partitions
the set state. This means that if the main partition also has delayed inputs, their delay times must elapse first
before the delay time of the virtual partition starts. When setting to unset, the delay inputs of the virtual parti-
tion follow this delay, if a delay is triggered in the main partition.
6.8

Chime Option

Chime
The chime function can be enabled for the burglar alarm inputs. This function permits the activation of the
keypad buzzer and the "Chime" output in the event of an input being triggered during unset. The buzzer is
activated for a short beep and the "Chime" output for one pulse.
For the buzzer (keypads and outputs), this function can be programmed as a separate parameter. The chime
function can be switched off by the user by pressing the @ key on the remote keypad.
6.9

Audio / Video Address

Link inputs [TM5162]
This menu function enables inputs and audio/video addresses to be linked. Any number of inputs can be
linked to an address. Each input can, however, be linked to only one address.
Link inputs request
The inputs which can be linked to an address can be requested in turn by pressing the ? key. For this pur-
pose, the indication with the choice of inputs is printed on the ? key. The system then shows the next input
which is linked to an address. Pressing the ? key again enables further linked inputs to be requested in the
same manner.
40
Siemens Building Technologies
Fire Safety & Security Products
Each input with its own delay time reacts only to this and does not follow any
other delay time. Exception: use of input types with the "exit delay terminator"
function ("Final Set" or "Final Door Set"). In the set state, triggered inputs with
IMPORTANT
their own delay time trigger an alarm immediately after the own delay time has
elapsed. This is also the case if a delay time of a different input in the same
partition has not yet elapsed.
NOTE
The chime can be switched on/off by user only for the default partition assigned to a keypad
address. Chime function in other partitions are still activated and can not be switched of.
Therefore it's recommended to use chime function only in 1 particular partition