Keypads; Default Partition; Keypad Mode; Leds Keypad - Siemens SI120 Configuration Manual

Table of Contents

Advertisement

10

Keypads

[TM514] Remote Key-
This menu function enables the following parameters to be programmed for each remote keypad.
pads
10.1

Default Partition

Partition Assignment in
The LEDs of the remote keypads can only indicate the status of one partition. But because several partitions
Idle State
can be controlled from one remote keypad, it is necessary to define which partition the LEDs indicate in the
idle state. Immediately a valid user PIN is entered and a partition is selected, the status of this partition is
immediately indicated.
10.2

Keypad Mode

Keypad Mode
In this menu it's defined, if the remote keypad is used as a "normal" remote keypad or as a "GV Geistiger
Verschluss" (IL Intellectual Lock) keypad.
Internal = The keypad works Normal without linking operation to GV input function.
External = The keypad works in combination with GV(IL). In this case the keypad operation is only acces-
10.3

LEDs Keypad

LEDs Keypad
LCD
Input status LCD
LED
10.4

Buzzer On

I: Entry Time
The buzzer is activated during the entry time (continuous tone) after triggering a delayed input
O: Exit Time
The buzzer is activated during the setting delay (continuous tone).
When a delayed input is triggered, the continuous tone changes to an intermittent tone (on/off) until all de-
layed inputs are in quiescent state.
A: Alarm
The buzzer is activated on an alarm (continuous tone).
C: Full Set Confirmation
The buzzer is activated for 3 seconds on a positive acknowledgement or outputs for 3 or 6 short buzzes on a
negative acknowledgement
H: Chime,
The buzzer is activated for a short beep and the "Chime" output for one pulse.
Siemens Building Technologies
Fire Safety & Security Products
Partition assignment in idle state (basic partition)
Security stage
Remote keypad type: normal/intellectual lock
Remote keypad buzzer
Setting without code
nd
sible with the 2
identification within 20 seconds, when the GV was triggered.
This parameter must always be set on.
Not relevant
Not relevant
NOTE
In combination with an SAK84/94 the buzzer is activated for 1.5 seconds.
NOTE
The chime can be switched on/off by user only for the default partition assigned to a keypad
address. Chime function in other partitions are still activated and can not be switched of. There-
fore it's recommended to use chime function only in 1 particular partition.
Keypads
61
07.2009