8.2.29 Chime

Chime
The chime function can be enabled for the burglar alarm inputs. This function permits the activation of the
keypad buzzer and the "Chime" output in the event of an input being triggered during unset. The buzzer is
activated for a short beep and the "Chime" output for one pulse.
For the buzzer (keypads and outputs), this function can be programmed as a separate parameter.
The chime function can be switched off in the general menu by the user simply by pressing the @ key.

8.2.30 Trouble (System)

Trouble (System)
This output is activated in the following cases:
The output is automatically reset after the end of the fault. In the case of transmission faults, it is also reset
by entering a valid user PIN.

8.2.31 Blockschloss

Blockschloss
The output is always activated except on unset or part set during:

8.2.32 Blockschloss 2

Blockschloss 2 GV
The same function as "Blockschloss for Germany" on unset / part set.
(Geistiger Verschluss /
In set state the output isn't activated either. The output in set state is controlled from a remote keypad or an
Intellectual lock)
input which is programmed to "Intellectual lock".
There are two possibilities available in the partition parameters for the intellectual lock:
"GV for unset only": This means that a "Blockschloss" with a "reset lockout" must be present. In the locked
state either a PIN code must be input on the GV remote keypad or a GV input activated. When this is done,
the block lock GV output is activated for 20 seconds, which means that the operator has 20 seconds in which
to open the "Blockschloss" and unset the system.
"GV for set and unset only": In this case a code has not only to be entered as described above to unset
the system but also to set it. The time is also limited to 20 seconds during setting.

8.2.33 Blockschloss Bosch

Blockschloss Bosch
For Blockschloss made by Bosch.
Siemens Building Technologies
Fire Safety & Security Products
Fault in telephone line
Mains power supply fault
Battery fault
Failure of fuses
E-Bus fault
Transmission fault
Fault
Tamper
Burglar alarm
Alarm in memory
Triggered burglar inputs without delay
Triggered panic alarm inputs
Triggered lock supervision
more than 50% of inputs in the partition are bypassed