General control card parameters (operator functionality)

6.
General control card parameters (operator functionality)
The operator parameters set the configuration of the G6 EtherCAT control. Furthermore, the
software version as well as the current status can be read.
Id-Text
os00
Meaning
Type
Data length
Access
Coding
Note
Id-Text
os02
Meaning
Type
Data length
Access
Coding
Note
Id-Text
os03
Meaning
Type
Data length
Access
Coding
Note
24
Name
operator identifier
Displays the control card type, as well as the software version.
Variable
32 bit
read
e.g.: 150508
15xxxx: G6
xx05xx: EtherCAT
xxxx08: Version of the configuration parameters
Standard value: Device dependent
-
Name
software date OS
Software date of the control card
Variable
32 bit
read
0.0000...9999, 3112:
The year is displayed before the comma, month and day are after that.
2012,0813 means 13.08.2012.
Standard value: 0.0000
-
Name
software version
Software version of the control card
Variable
32 bit
read
0.0.0.0...255.255.255.255
e.g.: 1.3.0.1
Standard value: 0.0.0.0
-
Parameter index
0x2080
Parameter index
0x2082
Parameter index
0x2083