OPeRATOR PARAMeTeR

5 Operator parameter
Figure 12:
Figure 13:

5.1 General control card parameters (Operator functionality)

os00
operator identifier
Value
Meaning
e.g.150117
Displays the control card type, as well as the software version.
15xxxx: G6
xx01xx: Analog/digital-control
xxxx17: Version of the configuration parameters
Inverter parameter
CP mode
Operator parameter
Settings
Operator parameter
os
Operator parameter
dp
LCD-parameter
Menu
Top Bottom
Select control board parameter group
In the following, only the meanings of the parameter values are described. Value
ranges, data length- and type; Access mode and the default values can be taken
from COMBIVIS.
Use the operator parameters to configure
the control card, the fieldbus (if available)
and the display.
With the keys <▲> and <▼> select "Op-
erator parameter" and confirm with <EN-
TER>.
The control card parameters at the analog
/ digital control are divided into two groups:
os - Operator system parameters; Display
and setting of the control board
dp - LCD-Display parameters; Configura-
tion of the LC display via bus
With the keys <▲> and <▼> select the
corresponding parameter group.
<ENTER> switches to the selected sub-
menu.