EtherCAT interface
Id-Text
co04
Type
Meaning
Data length
Access
Coding
Name
Meaning
Data length
Access
Coding
Name
Meaning
Data length
Access
Coding
Name
Meaning
Data length
Access
Coding
Name
Meaning
Data length
Access
Coding
10
Name
Identity object
Structure
Number of subindices of this object
8 bit
read
4
Standard value:4
Customer-ID
Includes manufacturer id. assigned by the CiA
32 bit
read
20: KEB
Standard value:20
Product code
Includes a unique value for this unit series.
32 bit
read
300000h...30FFFFh
Standard value:300000h : G6
Revision number
Includes in the low word the revision number of the G6 power unit. In the
high word the revision number of the control.
32 bit
read
00000000h...FFFFFFFFh
Standard value:-
KEB_device serial number
Includes the serial number of the unit.
32 bit
read
0...2147483647
Standard value:0
Subindex 0
Subindex 1
Subindex 2
Subindex 3
Subindex 4
Parameter index
0x1018