EtherCAT interface
Id-Text
fb01
Meaning
Type
Data length
Access
Coding
Note
Id-Text
co02
Meaning
Type
Data length
Access
Coding
Note
12
Name
Communication state
Display of the EtherCAT communication state
Variable
16 bit
read
Decimal values (bit-coded):
1
Error
2
started
4
ready to start
8
mailbox run
16 PDinRun
32 PDoutRun
Standard value:0
-
Name
ErrorRegister
Indicates the error status of the EtherCAT user
Variable
8 bit
read
Decimal values (bit-coded):
0
No error
1
Generioc error
2
Error overcurrent
4
Overvoltage or undervoltage error
Standard value:0
-
Parameter index
0x2181
Parameter index
0x1001