General control card parameters (operator functionality)
Id-Text
os13
Meaning
Type
Data length
Access
Coding
Note
Id-Text
os14
Meaning
Type
Data length
Access
Coding
Note
28
Name
operator state
Displays the status of the power unit, as well as the image of the power
unit parameter of the control board.
Variable
8 bit
read
Bit 0
reserved
Bit 1...2
LT-conf.-ID status
Bit 3...5
LT-image status
Bit 6...15 reserved
Standard value: 0
-
Name
store state
By writing of value "0" non-volatile parameters are saved immediately.
After completion of the storage the value jumps to status "1". If at the end
of the download lists in COMBIVIS the value "0" comes before value "1",
COMBIVIS will send the value as long as the inverter finishes storing.
Variable
8 bit
read / write
0: busy
1: ready
2: off
Standard value: 1
-
Parameter index
0x208D
0: Power unit-ID unknown
2: Power unit-ID OK
4: Power unit-ID incorrect
0: PU image not initialised
1: write PU image
3: PU image changed
4: PU image initialised
5: PU image check
6: PU image not available
Parameter index
0x208E