KEB COMBIVERT G6 series Programming Manual page 14

Control circuit; ethercat
Hide thumbs Also See for COMBIVERT G6 series:
Table of Contents

Advertisement

Process Data Mapping
Id-Text
fb11
Type
Meaning
Data length
Access
Coding
Note
Meaning
Data length
Access
Coding
Note
Id-Text
fb12
Type
Meaning
Data length
Access
Coding
Note
Meaning
Data length
Access
Coding
Note
14
Name
PD out subindex
ARRAY
Number of subindices of this object
8 bit
read
8
Standard value:8
-
The value of the subindex determines the parameter set of the selected
PD parameter. The value corresponds byte 1 of the DS301 parameter
co08.
8 bit
read / write
1...8 for subindex 1...8 (or rather set 0..7)
Standard value:1
-
Name
PD out offset
ARRAY
Number of subindices of this object
8 bit
read
8
Standard value:8
-
Specifies the offset of occupancy in the process data field. Position of the
value of the mapped parameter.
8 bit
read / write
0...15
Standard value:0
-
Parameter index
0x218B
Subindex 0
Subindex 1...8
Parameter index
0x218C
Subindex 0
Subindex 1...8