Preface
The operation of our products outside the indicated limit values of the technical data leads to
the loss of any liability claims.
1.6
Product description
The product family COMBIVERT G6 with safety function STO has been developed for the
use in safety-oriented applications. The basic standards as well as application and coun-
try-specific standards must be observed furthermore. The manual refer to standards that are
complementary to note!
This document is a description of the functions and parameters of the G6 - control card with
VARAN interface (Versatile Automation Random Access Network).
1.6.1
Overview of functions
The control provides the following functions:
•
hardware-installed supply of digital and analog inputs and outputs.
•
Diagnostic interface
•
Ethernet-based fieldbus interface (EtherCAT / Varan)
•
CAN fieldbus interface
•
Multi encoder interface
•
KTY interface
•
Brake control
•
STO functionality
•
Status LEDs
1.6.2
Safety function
The safety function STO according to IEC 61800-5-2 contains:
•
Safe torque off (Safe Torque Off - STO)
The safety function meet the requirements in accordance with performance level e (ISO13849-
1) and SIL 3 (IEC 61508 and IEC 62061). In case of proper project design, installation and
operation the safety function protects people against mechanical damages.
Attention
6
Validity of certificates
The certification of controllers with safety technology is only valid if the mate-
rial number corresponds with the specified numerical code und the FS logo
is printed on the type plate.