Technical Data; Operating Conditions; Climatic Ambient Conditions; Table 2: Climatic Ambient Conditions - KEB COMBIVERT H6 Instructions For Use Manual

Installation rectifier module
Hide thumbs Also See for COMBIVERT H6:
Table of Contents

Advertisement

OPERATING CONDITIONS

3 Technical Data

3.1 Operating conditions

3.1.1 Climatic ambient conditions

Storage
Surrounding temperature
Relative humidity
Storage height
Transport
Surrounding temperature
Relative humidity
Operation
Surrounding temperature
Air
Coolant inlet tem-
perature
Water
Relative humidity
Version and degree of protec-
tion
Site altitude
Table 2:
Climatic ambient conditions
All manuals and user guides at all-guides.com
Standard
Class
EN 60721-3-1
1K4
1K3
EN 60721-3-1
Standard
Class
EN 60721-3-2
2K3
EN 60721-3-2
2K3
Standard
Class
EN 60721-3-3
3K3
EN 60721-3-3
3K3
EN 60529
IP20
Notes
-25...55 °C
5...95 % (without condensation)
Max. 3000 m above sea level
Notes
-25...70 °C
95 % at 40 °C (without condensation)
Notes
5...40 °C (extended to -10...45 °C)
With temperature over 45 °C to max. 55 °C a
deration of 5 % per 1 K must be taken into con-
sideration.
5...40 °C (-10...45 °C)
5...40 °C
5...85 % (without condensation)
Protection against foreign material > ø12.5 mm
No protection against water
Non-conductive pollution, occasional conden-
sation when PDS is out of service.
Max. 2000 m above sea level
With site altitudes over 1000 m a derating
of 1 % per 100 m must be taken into con-
sideration.
With site altitudes over 2000 m, the control
board to the mains has only basic isola-
tion. Additional measures must be taken
when wiring the control.
25

Advertisement

Table of Contents
loading

Table of Contents