Host Application Objects
Extended Error Code
If the Error code equals FFh (Object specific error), the extended code will be translated as below:
Code
Contents
01h
Ownership
conflict
02h
Invalid
configuration
•
Connection Manager (06h), p. 33
•
Message segmentation
Anybus CompactCom 40 EtherNet/IP Transparent Ethernet Network Guide
CIP no.
CIP status code
01h
Connection
failure
10h
Device State
conflict
09h
Bad attribute
data
(CIP object)
Additional Information
The configuration data was supplied in a forward open request.
The configuration data was supplied in a set request to the As-
sembly object.
CIP extended error code: Use value from MsgData[2 - 3]. The
extended error code shall only be used if the request originated
from a Forward Open request, not for explicit set requests.
94 (144)