Chapter 4
Timeout Duration
Definition:
Timeout Duration is the time span of the read cycle and is repre-
sented in 10 mS increments. It is used in conjunction with External
Edge or Serial Trigger.
Usage:
It is useful in many tightly controlled applications which require a read
cycle to end before the next object appears and therefore need the
flexibility of a timeout adjustment.
Serial Cmd:
<K220,
end of read
Default:
100
(Corresponds to one second or 1000 mS.)
Options:
0 to 65535. (Divide any positive number entered by 100 to determine
the time in seconds.)
Note: A minimum setting of 2 is recommended.
Note: Timeout or Timeout or New Trigger under End of Read Cycle must be
enabled for Timeout Duration to take effect.
MS-3 Laser Scanner User's Manual
Read Cycle/Trigger
cycle,timeout
duration>
4-17
Need help?
Do you have a question about the MS-3 and is the answer not in the manual?
Questions and answers