Serial Trigger Character

Definition:
A single ASCII host serial trigger character that initiates the read cycle.
Serial Trigger Character is considered an on-line host command and
requires the same command format as all host commands: that is, to
be entered within angle brackets delimiters
Usage:
Allows the user to define the trigger character that initiates the read
cycle.
Serial Trigger Character (delimited)
Definition:
A delimited trigger character is one that either starts or ends the read
cycle and is enclosed by delimiters such as < >.
Usage:
Allows the user to define the trigger character that initiates the read
cycle.
Serial Cmd:
<K201, serial trigger
Default:
^]
(corresponds to <GS> displayed in the embedded menu)
Options:
Any single ASCII character, including control characters, except NUL
(00H), an existing host command character, or an on-line protocol char-
acter. Control characters entered on the command line are displayed in
the menu as mnemonic characters.
Note: Serial Data or Serial Data or Edge triggering mode must be enabled for
Serial Trigger Character to take effect.