(These commands are READ ONLY.)
Count
Definition
Returns the number of times the scanner has been re-powered or a
watchdog reset occurs.
Usage:
Useful for detecting unwanted resets caused by power supply problems
or ESD transients.
Serial Cmd:
Send <K406?>
Returns
<K406 power-on
Read Only
0 to 65,535 powerups, 0 to 65,535 resets.
Ranges:
Resets
Definition
Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware
defaults. A watchdog reset is a reset that is forced whenever the soft-
ware locks-up.
Usage:
Useful for detecting unwanted resets caused by power supply problems
or ESD transients.
Serial Cmd:
Send <K406?>
Returns
<K406
Read Only
0 to 65,535 powerups, 0 to 65,535 resets.
Ranges:
MS-3 Laser Scanner User's Manual
count,resets>
power-on count,resets>