Mechanical Installation

4 Mechanical Installation

4.1 Receiving and Unpacking the Unit

4.1.1 Items Supplied

Make sure that the items supplied and the
information on the labels correspond to the
order.
-
Top-level drive system. This label is
found on the control shelf, lower right
side of the LCP. See Illustration 3.2.
-
Drive module. This label is found inside
the drive module enclosure, on the right
side panel. See Illustration 3.1.
Visually check the packaging and the VLT
Parallel Drive Modules components for damage
caused by inappropriate handling during
shipment. File any claim for damage with the
carrier. Retain damaged parts, in case clarification
is needed.
VLT
AutomationDrive
R
www.danfoss.com
1
T/C: FC-302N710T5E00P2BGC7XXSXXXXAXBXCXXXXDX
2
P/N: 134X4109
S/N:
3
710 kW / 1000 HP, High Overload
4
IN: 3x380-500V 50/60Hz 1227/1129 A
5
OUT: 3x0-Vin 0-590Hz
800 kW / 1200 HP, Normal Overload
IN: 3x380-500V 50/60Hz
OUT: 3x0-Vin 0-590Hz
CHASSIS (OPEN TYPE) / IP00
Tamb. 45
˚
C/113
˚
F at Full Output Current
Max. Tamb. 55
˚
C/131
˚
F w/ Output Current Derating
SCCR 100 kA at UL Voltage range 380-500 V
ASSEMBLED IN USA
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
CAUTION - ATTENTION:
See manual for special condition / prefuses
Voir manuel de conditions speciales / fusibles
6
WARNING - AVERTISSEMENT:
Stored charge, wait 20 min.
Charge residuelle, attendez 20
`
1
Type code
2
Code number
3
Power rating
4
Input voltage, frequency, and current
5
Output voltage, frequency, and current
6
Discharge time
Illustration 4.1 Top-level Drive System Label (Example)
MG37K302
Installation Guide
®
123456H123
1260/1160 A
1422/1344 A
1460/1380 A
`
Danfoss A/S © 08/2017 All rights reserved.
VLT
AutomationDrive
R
www.danfoss.com
1
T/C: FC-BDMN250T5E00H2SXC7XXSXXXXAXBXCXXXXDX
2
P/N: 178N0025
S/N: 123456H123
Intended use - The Individual Base Drive
3
Modules are intended for use in Parallel Drive
Module system only. Speci c electrical
ratings are not applicable. Name plate of
Parallel Drive Module system should
be referred for actual drive ratings.
CHASSIS (OPEN TYPE) / IP00
SCCR 100 kA at UL Voltage range 380-500 V
ASSEMBLED IN USA
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
CAUTION - ATTENTION:
See manual for special condition / prefuses
Voir manuel de conditions speciales / fusibles
4
WARNING - AVERTISSEMENT:
Stored charge, wait 20 min.
Charge residuelle, attendez 20
`
1
Type code
2
Code number
3
Intended use disclaimer
4
Discharge time
5
Serial number
Illustration 4.2 Drive Module Label (Example)
NOTICE
LOSS OF WARRANTY
Removing the labels from the VLT
Modules can result in loss of warranty.
5
`
®