Danfoss VLT FC 102 Installation Manual page 64

Parallel drive modules 250–1200 kw
Hide thumbs Also See for VLT FC 102:
Table of Contents

Advertisement

Specifications
Encoder input accuracy (1–11 kHz)
The pulse and encoder inputs (terminals 29, 32, 33) are galvanically isolated from the supply voltage (PELV) and other high
voltage terminals.
1) Pulse inputs are 29 and 33.
Analog output
Number of programmable analog outputs
Terminal number
Current range at analog output
Maximum load GND - analog output
Accuracy on analog output
Resolution on analog output
The analog output is galvanically isolated from the supply voltage (PELV) and other high voltage terminals.
Control card, RS485 serial communication
Terminal number
Terminal number 61
7
7
The RS485 serial communication circuit is functionally separated from other central circuits and galvanically isolated from the
supply voltage (PELV).
Digital output
Programmable digital/pulse outputs
Terminal number
Voltage level at digital/frequency output
Maximum output current (sink or source)
Maximum load at frequency output
Maximum capacitive load at frequency output
Minimum output frequency at frequency output
Maximum output frequency at frequency output
Accuracy of frequency output
Resolution of frequency outputs
1) Terminals 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high voltage terminals.
Control card, 24 V DC output
Terminal number
Output voltage
Maximum load
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digital
inputs and outputs.
Relay outputs
Programmable relay outputs
Relay 01 terminal number
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
®
Relay 02 (VLT
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
62
VLT
1)
on 1–3 (NC), 1–2 (NO) (resistive load)
1)
(inductive load @ cosφ 0.4)
1)
on 1–2 (NO), 1–3 (NC) (resistive load)
1)
(inductive load)
AutomationDrive FC 302 only) terminal number
1)
on 4–5 (NO) (resistive load)
1)
on 4–5 (NO) (inductive load @ cosφ 0.4)
1)
on 4–5 (NO) (resistive load)
1)
on 4–5 (NO) (inductive load)
1)
on 4–6 (NC) (resistive load)
1)
on 4–6 (NC) (inductive load @ cosφ 0.4)
1)
on 4–6 (NC) (resistive load)
Danfoss A/S © 08/2017 All rights reserved.
®
Parallel Drive Modules
2)3)
overvoltage category II
Maximum error: 0.05% of full scale
0/4–20 mA
500 Ω
Maximum error: 0.5% of full scale
12 bit
68 (P, TX+, RX+), 69 (N, TX-, RX-)
Common for terminals 68 and 69
27, 29
0–24 V
40 mA
10 nF
32 kHz
Maximum error: 0.1% of full scale
12 bit
12, 13
24 V +1, -3 V
200 mA
1–3 (break), 1–2 (make)
240 V AC, 2 A
240 V AC, 0.2 A
60 V DC, 1 A
24 V DC, 0.1 A
4–6 (break), 4–5 (make)
400 V AC, 2 A
240 V AC, 0.2 A
80 V DC, 2 A
24 V DC, 0.1 A
240 V AC, 2 A
240 V AC, 0.2 A
50 V DC, 2 A
MG37K302