Installation

4.5 Mounting the terminating module

The bus module is now mounted.
4.5
Mounting the terminating module
The ET 200pro station must be terminated with the terminating module.
Prerequisites
Required tool: cross-tip screwdriver, size 2.
Procedure
Proceed as follows to mount the terminating module
1. Mount the terminating module onto the rack.
2. Slide the terminating module to the left up against the last bus module.
Note
Do not screw the terminating module to the rack (2 recessed head screws at the front,
torque 1.5 Nm) until all the bus modules are mounted and screwed in place.
The terminating module is included in the scope of delivery of the interface module.
Figure 4-7
36
Interface module
Bus module 155 mm
Mounting the terminating module
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB