4.
You have performed the acceptance test of the STO function.
A.5.2
Machine documentation
Machine or plant description
Designation
Type
Serial number
Manufacturer
End customer
Block diagram of the machine and/or plant:
...
Inverter data
Table A- 5
Hardware version of the safety-related inverter
Labeling the drive
...
...
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB
The inverter signals neither faults nor alarms of the safety
•
functions (r0945[0...7], r2122[0...7]).
The inverter signals the following:
•
"STO is selected" (r9773.0 = 1).
"STO is active" (r9773.1 = 1).
Deselect STO
4.1.
Deselect STO.
4.2.
Check the following:
STO is not active (r9773.1 = 0).
•
The inverter signals neither faults nor alarms of the safety
•
functions (r0945[0...7], r2122[0...7]).
...
...
...
...
...
...
...
Article number and hardware version of the inverter
...
...
A.5 Acceptance tests for the safety functions
...
...
Appendix
Status
...
...