7.3 Interface description
Note
The address switches, which are located beneath the cover for the Basic Operator Panel
BOP, have no function for the CU305 PN.
7.3.2.2

X150 P1 / P2 PROFINET

Table 7- 3
Connector type:
Data rate:
Note
The PROFINET interfaces support Auto MDI(X). It is therefore possible to use both crossed
and uncrossed cables to connect the devices.
There are four LEDs on the front panel of the CU305 PN to display status information about
the PROFINET interfaces (see Interface overview (Page 133)).
The table shows the status information these indicate.
Table 7- 4
LED
LNKx
ACTx
134
X150 P1 and X150 P2 PROFINET
Pin
Signal name
1
RXP
2
RXN
3
TXP
4
Reserved, do not use
5
Reserved, do not use
6
TXN
7
Reserved, do not use
8
Reserved, do not use
RJ45 socket
100 Mbits or 10 Mbits
LED states on the X150 P1/P2 PROFINET interface
Color
Status
-
Off
Green
Flashing light 0.5 Hz
Continuous light
-
Off
Yellow
Flashing light
Technical data
Receive data +
Receive data -
Transmit data +
-
-
Transmit data -
-
-
Description
Missing or faulty link
Connection establishment
10 or 100 Mbit link available
No activity
Data is being received or sent at port x
Manual, 07/2015, 6SL3097-4AC10-0BP5
SINAMICS S110