Accessories

9.1

DRIVE-CLiQ cabinet bushing

9.1.1

Description

A DRIVE-CLiQ cabinet bushing is used to connect the DRIVE-CLiQ cables between the
inside and outside of the control cabinet. It is used in a control cabinet panel. The data lines
and the voltage supply contacts of the DRIVE-CLiQ are also routed through the bushing. The
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ cables is available with DRIVE-CLiQ
connector and M12 connector/socket.
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ connectors
The cabinet bushing has degree of protection IP54 according to EN 60529 from the outside
towards the inside. Inside the control cabinet, a connection is established according to
degree of protection IP20 or IPXXB acc. to EN 60529. So that the complete outside of the
cabinet bushing, including the DRIVE-CLiQ interface, has degree of protection IP54, a
DRIVE-CLiQ cable must be used, which as a minimum must also have degree of protection
IP54.
DRIVE-CLiQ cabinet bushing for M12 plug/socket
The cabinet bushing has degree of protection IP67 according to EN 60529 from the outside
towards the inside. Inside the cabinet a connection according to degree of protection IP67 in
compliance with EN 60529 is realized.
9.1.2

Safety Information

NOTICE
Damage caused by the use of incorrect DRIVE-CLiQ cables
The use of incorrect or not released DRIVE-CLiQ cables can cause damage or functional
faults to devices or the system.
• Use only appropriate DRIVE-CLiQ cables that have been approved by Siemens for the
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5