X500 Drive-Cliq Interface - Siemens SINAMICS S110 Manual

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

8.3.3.2

X500 DRIVE-CLiQ interface

Table 8- 9
Connector
type
The blanking cover for the DRIVE-CLiQ port is included in the scope of delivery.
Blanking covers (50 x) Article No:: 6SL3066-4CA00-0AA0
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
Supplementary system components and encoder system integration
X500: DRIVE-CLiQ interface
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
Reserved, do not use
B
M (0 V)
DRIVE-CLiQ socket
8.3 Sensor Module Cabinet-Mounted SMC20
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Electronics ground
183

Advertisement

Table of Contents
loading

Table of Contents