Interface Description; Overview; X524 Electronics Power Supply - Siemens SINAMICS S110 Manual

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

8.5.3

Interface description

8.5.3.1

Overview

Figure 8-22
8.5.3.2

X524 electronics power supply

Table 8- 24
X524: Electronics power supply
Terminal
+
+
M
M
Type: Screw-type terminal (Page 263)
Max. cross section that can be connected: 2.5 mm²
The maximum cable length that can be connected is 30 m.
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
Supplementary system components and encoder system integration
Connection for the solenoid of the motor brake
Connection for the 24 VDC power supply
Connection for the pre-fabricated (CTRL) to the Power Module, Blocksize format
Interface description: Safe Brake Relay
Function
Electronics power supply
Electronics power supply
Electronics ground
Electronics ground
8.5 Option module Safe Brake Relay
Technical data
Voltage: 24 V (20.4 ... 28.8 V)
Current consumption: max. 0.3 A (without motor
holding brake)
Max. current via jumper in connector: 20 A (15 A
according to UL/CSA)
209

Advertisement

Table of Contents
loading

Table of Contents