7.7
Installation
Snap-mounting the CU305 onto the Power Mod-
ule (frame size FSA)
The procedure when mounting the Control Unit on the Power Module is independent of the
frame size of the Power Module.
Removing the Control Unit
Figure 7-14
To remove the Control Unit from the Power Module, press the blue release lever, shown in
the diagram, downward and swing the Control Unit out to the front.
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
Removing the CU305 from the Power Module (frame size FSA)
Power Module (frame size FSA) with CU305
CU305 Control Units
7.7 Installation
163