Siemens SINAMICS S110 Manual page 88

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Blocksize Power Modules (PM240-2)
4.4 Dimension drawings
Power Modules, Push Through for frame sizes FSA / FSB / FSC
Table 4- 15
Dimensions of the Power Modules
Frame size
Width
[mm]
FSA
FSB
FSC
The Power Modules can be mounted side by side. For tolerance reasons, we recommend a lateral clearance of 1 mm.
1)
For PT modules, the maximum wall thickness of the cabinet is 3.5 mm.
2)
Figure 4-12
88
Height [mm]
1)
None
Shield plate
126
238
154
345
200
411
Dimension drawing of PM240-2 Push Through Power Modules, frame size FSA, all data
in mm (inches)
Total depth
[mm]
with
Shield plate
322
171
430
171
500
171
Depth in the
Depth outside
2)
cabinet [mm]
the cabinet
117.7
117.7
117.7
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
[mm]
53.1
53.1
53.1