Power Supply Unit Module Specifications; Table 17 Ac Psu Specifications; Table 18 -48 Vdc Psu Specifications - Alcatel-Lucent 7750 SR-a4 Installation Manual

Service router
Table of Contents

Advertisement

System Specifications
Parameter
Rated voltage (DC)
Operating voltage range (DC)
Rated voltage (AC)
Operating voltage range (AC)

Power Supply Unit Module Specifications

Parameter
Dimensions (H x W x D)
Weight
Voltage range
Maximum current
Efficiency
Parameter
Dimensions (H x W x D)
Weight
Voltage range
Maximum current
Efficiency
52
Table 16: 7750 SR-a8 Environmental Specifications (Continued)
Notes:
1.
Short-term refers to no more than 96 consecutive hours per occurrence and no more than 15 occurrences in
a one-year period.
2.
Pollution degree is as defined in IEC 60950. Pollution Degree 2 applies where there is only non-conductive
pollution that might temporarily become conductive due to occasional condensation.
Table 17: AC PSU Specifications
Table 18: –48 VDC PSU Specifications
Description
–48 VDC
–40 to –72 VDC
120 or 240 VAC
90 to 264 VAC
Description
3.4 x 7.78 x 1.59 in. (8.64 x 19.77 x 4.05 cm)
2.33 lb (1.06 kg)
90 to 264 VAC
12 A
93%
Description
3.4 x 7.78 x 1.57 in. (8.6 x 19.77 x 3.99 cm)
2.44 lb (1.108 kg)
–40 to –72 VDC
40 A
93%